Product
SIR-8000 series

Multiple voltage test capabilities: 300V, 500V, 1000V

Multi-threshold judgment function 

Real-time current monitoring function 

Remote monitoring, computer & mobile phone synchronization function  

Support test and pre-check function: Prevent short-circuit of objects under test

Support error status prompt, local alarm and mobile phone intelligent prompt (optional)  

Provide annual patrol inspection and calibration service 

Chinese operation software and data analysis function 

TECHNICAL INDEX

Industry Applications
Applies to HDI, FPC, chip packaging substrate, PCB auxiliary materials, etc.


Product Introduction
1. Flexible, multi-channel and group test capability
Establish multi groups of test modes to test different samples in 1-4 environmental test chambers according to the test demands.
2. Wide-range bias voltage and test voltage
The test voltage includes 300V, 500V and 1000V, and can be set randomly within 1.0V ~ 1000V, and the positive and negative bias voltage can be switched during the test.
3. Real-time current detection capability
During the test, the 10 times/s micro-current monitoring module can draw the working status of ionic migration process between channels for material analysis.
4. Threshold judgment of multiple insulation values
Support multiple judging criteria of insulation resistance threshold, for example, the test will be disconnected after single or multiple triggering of insulation resistance threshold, or lower than threshold running time.
5. Test system software developed for domestic clients
Fully conform to the special test requirements of different clients. Fitted with data analysis function to make the test software simpler and better.
6. International and industrial standards of insulation resistance test
IPC-TM-650 2.5.10/2.6.11/2.6.3/2.6.14 IEC-61189-5 IEC1086 IS0-9455-17, etc.
7. Remote functions of insulation resistance system
Support remote connection and control of Windows system desktop through the platform of Win, Android, iOS and Mac, to realize remote control and viewing of computer and operation of test software.


System Parameters

Model

300V

500V

1,000V

Number of channels

128/256

Number of test groups

Standard configuration: 2~4 groups (64 channels/group); 32 channels/group optional

Working hours

1~9,999 hours (adjustable)

Bias voltage

-100~+300VDC

-100~+500VDC

-100-+1,000VDC

Polarity inversion

Available

Common-pole test

Common positive pole

CAF test (optional)

Available

Test voltage

1.0~100VDC (0.01V stepping)

>100VDC (0.1V stepping)

Voltage rise cascade

100V (>100V)

Precision of test voltage

±0.1V (1.0-100VDC)

±0.5V (>100VDC)

Test scope of resistance

1x105~3x1013Ω

1x105~5x1013Ω

1x105~1x1014Ω

 

1x106~1x1010Ω≤±5.0%

1x106~1x1010Ω≤±5.0%

1x106~1x1010Ω≤±5.0%

 

(Test voltage 5V)

(Test voltage 5V)

(Test voltage 5V)

 

1x1010~1x1011Ω≤±10%

1x1010~1x1011Ω≤±10%

1x1010~1x1011Ω≤±10%

Resistance test precision

(Test voltage 5V)

(Test voltage 5V)

(Test voltage 5V)

1x1011~1x1012Ω≤±15%

1x1011~1x1012Ω≤±15%

1x1011~1x1012Ω≤±15%

 

(Test voltage 50V)

(Test voltage 50V)

(Test voltage 50V)

 

1x1012~1x1013Ω≤±20%

1x1012~1x1013Ω≤±20%

1x1012~1x1013Ω≤±20%

 

(Test voltage 300V)

(Test voltage 500V)

(Test voltage 1,000V)

Resistance test speed

3.5s/channel (typical)

Full channel <10min

Scope of real-time current monitoring

0.1 ~ 300μA

0.1 ~ 500μA

0.1 ~ 1,000μA

Speed of real-time current detection

10 times/channel

Test interval

5min~600min (adjustable) 

Voltage rise cascade

1s~600s (adjustable)

Protection resistance

1

Test cable

Teflon (>1014Ω -55~200); standard configuration: 3.0m

Time of continuous power supply by UPS

15min

Overall dimensions

1,800x600x1,000 (mm) (HxWxD)

Net weight

128 channels: about 280kg

128 channels: about 280kg

128 channels: about 280kg

256 channels: about 300kg

256 channels: about 300kg

256 channels: about 300kg

Input voltage

AC 220V±10%, 50Hz

Service Hotline
021-31266656
Telephone
021-31266656