Product
Hot Oil Machines

Real-time multi-channel resistance and temperature data collection

Configurableupper and lower channel limits with channel screening function

Real-timedisplay of resistance variation rate,failed samples,and failure judgment value

Dynamic modification of reference resistance value

Dynamic report generation

TECHNICAL INDEX

Application

Widely used in HDI,chip package substrates, and other PCB industries.

 

Product overview

The hot oil machine online resistance test system monitors resistance changes in samples placed in a hot oil machine test chamber. Hardware collects resistance and temperature data in real-time, while the software provides automatic failure detection, real-time data analysis, and dynamic report output functions. It enables real-time monitoring of sample faiure conditions and swiftly generates test data analysis reports.

 

Hot oil online analysis software

1. Channelscreening before testing to detect potential open circuit issues.

2. Automatic range selection for suitable measurement.

3. Real-time data analysis adds the following to the orginal real-time test data tabe: test value, high-temperature resistance variation rate, maximum high-temperature variation rate, low-temperature resistance variation rate, maximum low-temperature variation rate, total test cycles, current test cycle failure cycle, and open circuit cyctle.

4. Real-time display of the proportion of failed samples.

5. Mutiple automatic faiure detection methods, including resistance conversion standards channel standard conversion, and cycle standards.

6. Dynamic modification of the test reference resistance value.

 

System parameters

Test scope of resistance

0.1MΩ-1MΩ

Resistance test precision

±(0.3%RD+0.1mΩ)

Resistance rang

1Ω、10Ω、100Ω、1KΩ、10KΩ、100KΩ、1MΩ

Test current

≤10mA

Test method

Four-wire system test method

Number of channels

40CH/60CH/80CH/96CH(optional)

Sampling rate

50ms/CH

Temperature acquisiton

NI temperature acquisition device, K-type thermocouple sensor

Temperature measurement range

-70℃~+200℃/0℃~+320℃(optional)

Temperature measurement accuracy

±0.5℃

Temperature resolution

0.01℃

Test mode

Temperature-triggered and timed testing

Cable specifications

High-temperature-resistant teflon cable,short-term resistance to 300℃, wire diameter: 0.12mm²

Cable protection

Extermal cables are protected by nylon sleeves,internal cables are protected by high-temperature-restant transparent heat-shrink tubing

Cable identification

Each group of internal cables is labeled by group and channel

Sample connection

Welding

Power supply voltage

AC 220V 10%, 1KW

Overall dimensions

1600*600*800(mm)

Net weight

About 150kg

 

Hot oil machine adapter

Number of channels in adapter box: 40 channels, dvided into 4 aviation plugs, each with 10 channels. Aviation plug: Civil-use 50-pin standard connectors

Dimensions: 46 mm(Diameter)

Connection method: Four-wire, 4 in 4 out

Volume: 76*260*300mm (HxWxD)

Service Hotline
021-31266656
Telephone
021-31266656